Quick Details
Standard parameters: 5-lead ECG, SpO2(F-5),NIBP, TEMP,RESP,PR,HR.
Optional: Touch Screen, Thermal Recorder, 3/12-lead ECG, 2/4-IBP,4-TEMP,2-SpO2, Nellcor/Masimo SpO2,BIS, Phaisein/ Respironics Multi-gas, ICG/CO, FHR, FM, TOCO,
Packaging & Delivery
Packaging detail:Standard export package Delivery detail:within 7-10 workdays after receipt of payment |
Specifications
AMMP13 Patient Monitor with Separated Para Board
Features &Benefits: 1.15” color TFT display, high resolution: 1024×768dpi; 2.Separated para board: ECG, NIBP, SpO2 board; 3.Full touch-screen enables intuitive operation by clicking one the specific parameters or the waveform in real time, standard configuration includes the navigation knob. 4.Real time S-T segment analysis, and ARR analysis; 5.SpO2 Pitch Tone Variation and Drug Dose Calculation; 6.Parameter waveform and characters color selectable 7.Multi-display: Standard, Large font, Trend Coexis, OxyCRG dynamic 8.Standby mode for Energy saving and suspend monitoring; 9.7-lead ECG waveforms display in phase; 10.Capture dynamic waveforms; 11.Built-in rechargeable lithium battery, and battery volume checking, 12.AC power checking 13.Efficient resistance to interference of defibrillator and HF knife; 14.SINNOR F-6 SpO2 technology, VS NELLCOR accuracy; 15.Networking capacity and TCP/IP networking platform enable abundant future upgrade 16.Time delay switch-off function keep the monitor data restart monitor; 17.Complete and flexible mounting solution for transportation and in-patient monitoring Standard parameters: 5-lead ECG, SpO2(F-5),NIBP, TEMP,RESP,PR,HR. Optional: Touch Screen, Thermal Recorder, 3/12-lead ECG, 2/4-IBP,4-TEMP,2-SpO2, Nellcor/Masimo SpO2,BIS, Phaisein/ Respironics Multi-gas, ICG/CO, FHR, FM, TOCO,
AMMP13 Patient Monitor with Separated Para Board
Performance Specifications Display: 15”color TFT Rolling and refreshing waveform display Resolution: 1024×768 Multi display selectable including: Large-font display Trend coexist display OxyCRG dynamic view display. Bed-to-bed view display Trace: 9 waveforms(7 ECG, 1 SPO2 and 1 RESP) Sweep speed:12.5mm/s,25mm/s,50mm/s Indicator: Power/battery indicator light QRS beep and alarm sound Battery: Rechargeable lead acid cell, 12v/4AH Max.24 hour for charging, 4 hours for continue working Trend: Parameter graphic and tabular trends: 5s/piece,8 hours; 1min/piece,168 hours(24hour×7days) 5min/piece,1000 hours. Storage: NIBP: 1000 groups Alarm: 200 groups Full disclosure waveforms: 3600S SD card external storage Alarm: User-adjustable High, Medium and Low limits 3-level Audible and visual alarm Networking: Connected to central monitoring system TCP/IP netting platform Recorder: Build-in, thermal array Plethysmogram caveform:2 channels Record mode: manual, on alarm, time-defined Recording width: 50mm Printing speed: 50mm/s Recording type: Frozen waveform record NIBP recall record Trend table record Alarm record Fixed -time record
AMMP13 Patient Monitor with Separated Para Board
Standard parameter: ECG: Lead mode:5 –lead(R,L,F,N,C) Lead selection :I,II,III,avR,avL,avF,V Waveform: 3 and 7 channel selectable Gain selection: 0.5mm/mv,1mm/mv,2mm/mv Sweep speed: 12.5mm/s;25mm/s;50mm/s Heart rate range: Adult: 15~300bpm; Neonate/pediatric:15~350bpm Accuracy: +1bpm or +1%,whichecer is greater Resolution: 1bpm Filter:surgery mode:1~20Hz monitor model:0.5~40Hz Diagnostic mode:0.05~130Hz Scaling signal: 1mv,+3% Protection: withstand 4000VAC/50 voltage isolation against electrosurgical interference and defibrillation Alarm range: 15~350bpm S-T segment detecton: Measurement range: 2.0mV~+2.0mV Alarm Range: -2.0mV~ +2.0mV Accuracy: -0.8mV ~+0.8Mv Error: +0.02Mv Arrhythmia analysis: YES SPO2 Measurement range: 0~100% Resolution: 1% Accuracy: +2%(70-100%);0-69% unspecified Alarm range 0~100% Pluse Rate: range: 20~300bpm Resolution: 1bpm Error: +1bpm or +2%,whichever is greater NIBP Method: Digital Automatic oscillometric Operation mode : Manual/Automatic/continuous Auto measurement time: Adjustable(1~480min) Measurement Unit: mmHg/Kpa selectable Measurement types: Systolic, Diastolic, Mean Measurement tange: Range of Systolic pressure: Adult: 40~270mmHg Pediatric: 40~220mmHg Neonate: 40~135mmHg Range of mean pressure: Adult: 20~235mmHg Pediatric: 20~165mmHg Neonate: 20~110mmHg Range of diastolic pressure: Adult: 10~215mmHg Pediatric: 10~150mmHg Neonate :10~100mmHg Over-pressure protection: Double safety protection Resolution: 1 mmHg Alarm: Systolic.Diastolic,Mean RESPIRATION Method: Thoracic impedance Measurement range: Adult:7~120rpm; Neonate/Pediatric:7~150rpm Apnea alarm: YES,10~40s Resolution: 1rpm Accuracy: +2rpm AMMP13 Patient Monitor with Separated Para Board TEMPERATURE Compatible probe: YSI or CYF Measurement range: 5~50℃ Resolution : 0.1℃ Accuracy: +0.1℃ Refreshing time: about 1 Average measuring time: <10s FHR Transducer: Multi-crystal, Pulsed Doppler Measurement range: 50~210 BPM Working frequency: 1 MHz Strength: <5mW/cm[] Signal processing: special DSP system and modern recognization. Resolution: 1BPM Accuracy: ±1BPM Alarm Range: High: 160,170,180,190 BPM, Low: 100,110,120 BPM FM Manual button marking, automatic FM identifying function TOCO Measuring Transducer: External pressure transducer Measurement range: 0~100 units Resolution: 1rpm Accuracy: ±2 rpm IBP Channel: 2 channels Range: -50-300mmHg Resolution: 1mmHg Accuracy: ±4mmHg(±4%) Unit: mmHg, Kpa Converter Sensitivity: 5V/V/mmHg Transducer sites: ART/PA/CVP/LAP/RAP/ICP EtCO2( Sidertream CO2) Measurement range: 0~99mmHg Accuracy: +2mmHg (0~40mmHg) Sampling Range: 100ml/min Sampling rate accuracy: 15% Respiration rate: 0~120rmp Respiration accuracy: +2rmp (0~70rmp) +5rmp (>70rmp) Respiration time: <240msec (10% to 90%) Delay time: <2s EtCO2 (mainstreaam CO2) Method: Infrared Spectrum Range: 0.0-10% (0~76%) Resolution: 1mmHg (0.1%) Accuracy: <5%(±4.0 mmHg) Or<10%(of Readings) Recorder: Build-in, thermal array Plethysmogram caveform:2 channels Record mode: manual, on alarm, time-defined Recording width: 50mm Printing speed: 50mm/s Recording type: Frozen waveform record NIBP recall record Trend table record Alarm record Fixed -time record Miscellaneous Satety: Safety level: Class I, type CF Dimendion and Weight Dimendion: 28*42*48cm G.Weight: <6.5KS Operation Environment Temperature: Working 0~+40℃ Transportation and storage –20~+60℃ Humidity: working≤85% Transportation and storage≤93% Power: AC 100-240,50/60Hz Patient range: Neonate,pediatric,and adult patients Accessories supplies (1) 5 lead ECG cable (2) 1 spo2 probes (3) 1 NIBP prbe (4) 1 temp probe (5)1 ground connecting liner (6) Chest electrode (10pcs/set)
AM Packaging and Shipping:AM Medical product with Inner foam outer carton packaging and cooperate with DHL,FEDEX,UPS,EMS,TNT,etc.International shipping company,make your goods arrive destination safely and quickly.