H7c82f9e798154899b6bc46decf88f25eO
H9d9045b0ce4646d188c00edb75c42b9ek

AMMP13 Patient Monitor with Separated Para Board

Short Description:

Product Name:AMMP13 Patient Monitor with Separated Para Board
Latest Price:

Model No.:AMMP13
Weight:Net weight: Kg
Minimum Order Quantity:1 Set Set/Sets
Supply Ability:300 Sets per Year
Payment Terms:T/T,L/C,D/A,D/P,Western Union,MoneyGram,PayPal


Product Detail

Product Tags

Quick Details

Standard parameters: 5-lead ECG, SpO2(F-5),NIBP, TEMP,RESP,PR,HR.

Optional: Touch Screen, Thermal Recorder, 3/12-lead ECG, 2/4-IBP,4-TEMP,2-SpO2, Nellcor/Masimo SpO2,BIS, Phaisein/ Respironics Multi-gas, ICG/CO, FHR, FM, TOCO,

Packaging & Delivery

Packaging detail:Standard export package
Delivery detail:within 7-10 workdays after receipt of payment

Specifications

AMMP13 Patient Monitor with Separated Para Board

Features &Benefits: 1.15” color TFT display, high resolution: 1024×768dpi; 2.Separated para board: ECG, NIBP, SpO2 board; 3.Full touch-screen enables intuitive operation by clicking one the specific parameters or the waveform in real time, standard configuration includes the navigation knob. 4.Real time S-T segment analysis, and ARR analysis; 5.SpO2 Pitch Tone Variation and Drug Dose Calculation; 6.Parameter waveform and characters color selectable 7.Multi-display: Standard, Large font, Trend Coexis, OxyCRG dynamic 8.Standby mode for Energy saving and suspend monitoring; 9.7-lead ECG waveforms display in phase; 10.Capture dynamic waveforms; 11.Built-in rechargeable lithium battery, and battery volume checking, 12.AC power checking  13.Efficient resistance to interference of defibrillator and HF knife; 14.SINNOR F-6 SpO2 technology, VS NELLCOR accuracy; 15.Networking capacity and TCP/IP networking platform enable abundant future upgrade 16.Time delay switch-off function keep the monitor data restart monitor; 17.Complete and flexible mounting solution for transportation and in-patient monitoring   Standard parameters: 5-lead ECG, SpO2(F-5),NIBP, TEMP,RESP,PR,HR. Optional: Touch Screen, Thermal Recorder, 3/12-lead ECG, 2/4-IBP,4-TEMP,2-SpO2, Nellcor/Masimo SpO2,BIS, Phaisein/ Respironics Multi-gas, ICG/CO, FHR, FM, TOCO,

AMMP13 Patient Monitor with Separated Para Board

Performance Specifications Display:      15”color TFT Rolling and refreshing waveform display Resolution: 1024×768 Multi display selectable including: Large-font display Trend coexist display OxyCRG dynamic view display. Bed-to-bed view display Trace:           9 waveforms(7 ECG, 1 SPO2 and 1 RESP) Sweep speed:12.5mm/s,25mm/s,50mm/s Indicator:         Power/battery indicator light QRS beep and alarm sound Battery:         Rechargeable lead acid cell, 12v/4AH Max.24 hour for charging, 4 hours for continue working Trend:             Parameter graphic and tabular trends: 5s/piece,8 hours; 1min/piece,168 hours(24hour×7days) 5min/piece,1000 hours.   Storage:    NIBP: 1000 groups Alarm: 200 groups Full disclosure waveforms: 3600S SD card external storage Alarm:        User-adjustable High, Medium and Low limits 3-level  Audible and visual alarm Networking:       Connected to central monitoring system TCP/IP netting platform Recorder:       Build-in, thermal array Plethysmogram caveform:2 channels Record mode: manual, on alarm, time-defined  Recording width: 50mm Printing speed: 50mm/s Recording type:   Frozen waveform record NIBP recall record Trend table record Alarm record Fixed -time record

AMMP13 Patient Monitor with Separated Para Board

Standard parameter: ECG:   Lead mode:5 –lead(R,L,F,N,C) Lead selection :I,II,III,avR,avL,avF,V Waveform:    3 and 7 channel selectable Gain selection: 0.5mm/mv,1mm/mv,2mm/mv Sweep speed: 12.5mm/s;25mm/s;50mm/s Heart rate range:   Adult: 15~300bpm; Neonate/pediatric:15~350bpm Accuracy: +1bpm or +1%,whichecer is greater Resolution:    1bpm Filter:surgery mode:1~20Hz monitor model:0.5~40Hz Diagnostic mode:0.05~130Hz Scaling signal: 1mv,+3% Protection:      withstand 4000VAC/50 voltage isolation against electrosurgical interference and defibrillation Alarm range: 15~350bpm S-T segment detecton: Measurement range:    2.0mV~+2.0mV                             Alarm Range:          -2.0mV~ +2.0mV Accuracy:              -0.8mV ~+0.8Mv Error:                 +0.02Mv   Arrhythmia analysis:   YES   SPO2 Measurement range:        0~100% Resolution:                1% Accuracy:                 +2%(70-100%);0-69% unspecified Alarm range               0~100% Pluse Rate:                 range:                 20~300bpm Resolution:             1bpm Error:                 +1bpm or +2%,whichever is greater   NIBP Method:                   Digital Automatic oscillometric Operation mode :            Manual/Automatic/continuous Auto measurement time:      Adjustable(1~480min) Measurement Unit:          mmHg/Kpa selectable Measurement types:         Systolic, Diastolic, Mean   Measurement tange: Range of Systolic pressure:    Adult: 40~270mmHg Pediatric: 40~220mmHg Neonate: 40~135mmHg Range of mean pressure:      Adult: 20~235mmHg Pediatric: 20~165mmHg Neonate: 20~110mmHg Range of diastolic pressure:   Adult: 10~215mmHg Pediatric: 10~150mmHg Neonate :10~100mmHg Over-pressure protection:     Double safety protection Resolution:                 1 mmHg Alarm:                    Systolic.Diastolic,Mean     RESPIRATION Method:                     Thoracic impedance Measurement range:           Adult:7~120rpm; Neonate/Pediatric:7~150rpm Apnea alarm:                 YES,10~40s Resolution:                   1rpm Accuracy:                    +2rpm   AMMP13 Patient Monitor with Separated Para Board   TEMPERATURE Compatible probe:             YSI or CYF Measurement range:           5~50℃ Resolution :                   0.1℃ Accuracy:                    +0.1℃ Refreshing time:               about 1 Average measuring time:        <10s   FHR Transducer:   Multi-crystal, Pulsed Doppler Measurement range:  50~210 BPM Working frequency:   1 MHz Strength:   <5mW/cm[] Signal processing:   special DSP system and modern recognization. Resolution:   1BPM Accuracy:    ±1BPM  Alarm Range:  High: 160,170,180,190 BPM,  Low: 100,110,120 BPM   FM Manual button marking, automatic FM identifying function   TOCO Measuring Transducer:  External pressure transducer Measurement range:  0~100 units Resolution:  1rpm Accuracy:  ±2 rpm   IBP Channel: 2 channels Range: -50-300mmHg Resolution: 1mmHg Accuracy: ±4mmHg(±4%) Unit: mmHg, Kpa Converter Sensitivity: 5V/V/mmHg Transducer sites: ART/PA/CVP/LAP/RAP/ICP   EtCO2( Sidertream CO2) Measurement range:   0~99mmHg Accuracy:   +2mmHg (0~40mmHg) Sampling Range:   100ml/min Sampling rate accuracy:   15% Respiration rate:   0~120rmp Respiration accuracy:  +2rmp (0~70rmp) +5rmp (>70rmp) Respiration time:   <240msec (10% to 90%) Delay time:  <2s   EtCO2 (mainstreaam CO2) Method:   Infrared Spectrum Range:   0.0-10% (0~76%) Resolution:   1mmHg (0.1%) Accuracy:   <5%(±4.0 mmHg)          Or<10%(of Readings)   Recorder:      Build-in, thermal array Plethysmogram caveform:2 channels Record mode: manual, on alarm, time-defined  Recording width: 50mm Printing speed: 50mm/s Recording type:  Frozen waveform record NIBP recall record Trend table record Alarm record Fixed -time record     Miscellaneous Satety:               Safety level: Class I, type CF   Dimendion and Weight Dimendion:      28*42*48cm          G.Weight:        <6.5KS   Operation Environment Temperature:    Working 0~+40℃ Transportation and storage –20~+60℃ Humidity:       working≤85% Transportation and storage≤93% Power:          AC 100-240,50/60Hz Patient range:    Neonate,pediatric,and adult patients   Accessories supplies (1) 5 lead ECG cable   (2) 1 spo2 probes   (3) 1 NIBP prbe   (4) 1 temp probe (5)1 ground connecting liner   (6) Chest electrode (10pcs/set)

AM Packaging and Shipping:AM Medical product with Inner foam outer carton packaging and cooperate with DHL,FEDEX,UPS,EMS,TNT,etc.International shipping company,make your goods​ arrive destination safely and quickly.


  • Previous:
  • Next:

  • Leave Your Message:

    Write your message here and send it to us.

    Leave Your Message:

    Write your message here and send it to us.