Wholesale Vascular Doppler Detector - high frequency 5.0KW mobile digital C arm X ray machine AM-M20B – Amain Detail:
Product Description
AR-M20B high frequency 5.0KW mobile digital C arm X ray machine
Features:
1. With a compact appearance, and easy to operate.
2. Unique base electric auxiliary support arm design, it’s more security for using.
3. A unique hand-held controller design, convenient to operate.
4. With a high-quality knockdown X-ray generator to reduce radiation.
5. With the Perspective KV,MA automatically track fluoroscopy to make the image brightness and clearness optimum.
6. Toshiba image intensifier three view, the quality is stable and reliable, a good image clarity.2. Automatic dynamic motion detection when fluoroscopy to avoid movement-related blurring, no silhouette8. Image acquisition and processing workstation
Registration
registration, medical records, Worklist
Collection
Start collection; prepare video, reset, horizontal mirror, vertical mirror, window adjustment, magnifying glass,negative image
Open silhouette, edge enhancement, recursive noise reductionProcessing
four windows, nine windows, sharpening, horizontal mirror, vertical mirror, text annotation, length measurement report save,
preview, expert template
Dicom features
Dicom browsing, web service
Automatically track fluoroscopy to make the image brightness and clearness optimum; Installation of dense grain grids, to further
enhance image sharpness
Features:
1. With a compact appearance, and easy to operate.
2. Unique base electric auxiliary support arm design, it’s more security for using.
3. A unique hand-held controller design, convenient to operate.
4. With a high-quality knockdown X-ray generator to reduce radiation.
5. With the Perspective KV,MA automatically track fluoroscopy to make the image brightness and clearness optimum.
6. Toshiba image intensifier three view, the quality is stable and reliable, a good image clarity.2. Automatic dynamic motion detection when fluoroscopy to avoid movement-related blurring, no silhouette8. Image acquisition and processing workstation
Registration
registration, medical records, Worklist
Collection
Start collection; prepare video, reset, horizontal mirror, vertical mirror, window adjustment, magnifying glass,negative image
Open silhouette, edge enhancement, recursive noise reductionProcessing
four windows, nine windows, sharpening, horizontal mirror, vertical mirror, text annotation, length measurement report save,
preview, expert template
Dicom features
Dicom browsing, web service
Automatically track fluoroscopy to make the image brightness and clearness optimum; Installation of dense grain grids, to further
enhance image sharpness
Specification
| Fluoroscopic Capacity |
Photography Max rated capacity | 5KW | ||
| Fluoroscopic ax rated capacity | Tube Current 4mA, Tube Voltage 120kV | |||
| Automatic Fluoroscopy | Tube Voltage: 40kV~120kV adjust automatically Tube Current: 0.3mA~4mA adjust automatically |
|||
| Manual Fluoroscopy | Tube Voltage: 40kV~120kV Continuous Tube Current: 0.3mA~4mA Continuous |
|||
| Pulse Fluoroscopy | Tube Voltage:40kV~120kV Continuous Tube Current: 0.3mA~8mA Continuous (1) intelligent frequency conversion technology is more advanced(2) improves the quality of single-frame images and reduces the amount of radiation (3) the tube is protected, continuous working time is extended (4) frequency: 0.5 ~ 8pps (frame / s) pulse length |
|||
| Photography Tube Voltage and mA | 40 kV~120 kV 20-100mA 1.0mAs~180mAs | |||
| Plate holder Size | 200mm×250mm(8″×10″) or 250mm×300mm(10″×12″) | |||
| X-ray Tube | X-ray Tube Special for High Frequency | Fixed anode Dual-focus, 0.3/1.5, Inverter Frequency: 40KHz |
||
| Anode capacity: 35KJ (47KHU) Tube thermal capacity: 650kJ(867kHu) |
||||
| Video System | Image Intensifier | Image Intensifier made by TOSHIBA (9″) Three view(9inch/ 6 inch / 4.5 inch) E5764SD-P3 Image definition indicators 12 bit |
||
| CCD Video camera | 1 Mega Ultra low-light CCD camera | |||
| Monitor | 19″LCD monitor *2:Resolution 1280*1024, | |||
| CCU(central control) | Recursive Filter: K=8, 8 images storage, image upright, image overturn, positive & negative image;LIH(last image freeze, and OSD (monitor display) |
|||
| Structural Performance | Directive wheel | ±90°revolution, can freely change the moving direction of the unit. | ||
| C-arm | Forward and Backward Movement: 200mm Up and down:400mm Revolution around Horizontal Axis: ±180° Revolution around Vertical Axis: ±15° Focus screen distance: 960mm C-arm opening: 740mm C-arm arm depth: 640mm Slide along the orbit: 120°(+90°~ -30°) |
|||
Product detail pictures:



Related Product Guide:
It is our responsibility to meet your needs and efficiently serve you. Your satisfaction is our best reward. We are looking forward to your visit for joint growth for Wholesale Vascular Doppler Detector - high frequency 5.0KW mobile digital C arm X ray machine AM-M20B – Amain, The product will supply to all over the world, such as: Colombia , Cape Town , Macedonia , We always stick to the tenet of "sincerity, high quality, high efficiency, innovation". With years of efforts, we have established friendly and stable business relationships with worldwide customers. We welcome any of your inquiries and concerns for our products, and we are sure that we will offer just what you want, as we always believe that your satisfaction is our success.