Product Description
AW-1A CE approved Hospital Movable Types Baby Medical Neonatal Radiant Infant Warmer Price
Features
Three modes: pre-warm, manual and automatic
Set temperature and skin temperature display separately
Anti-explosion micro crystal quartz for radiation source
Self – testing function, various failure alarms by audible and visual
APGAR timer to record therapy time
Convenient X-ray cassette tray under infant mattress
Heater head can be adjusted ± 90° horizontally
Inclination of infant bed is adjustable
LED observe light angle is adjustable
Transparent protector can be folded down, with two infusion seals
RS232 connector
Three modes: pre-warm, manual and automatic
Set temperature and skin temperature display separately
Anti-explosion micro crystal quartz for radiation source
Self – testing function, various failure alarms by audible and visual
APGAR timer to record therapy time
Convenient X-ray cassette tray under infant mattress
Heater head can be adjusted ± 90° horizontally
Inclination of infant bed is adjustable
LED observe light angle is adjustable
Transparent protector can be folded down, with two infusion seals
RS232 connector
Standard Configuration
Main body (including the Radiant source, Control system, Infant bed, Bracket), X-ray cassette, Observe light, I.V. pole, Skin
temperature sensor, Tray, Mattress, Transparent protector, Castors, Drawers
Optional Functions
Low pressure aspirator
LED phototherapy unit
Built-in infant resuscitator
Oxygen supply system
Electric Elevator
Specification
|
Power supply
|
AC110/220V, 60/50Hz
|
||||||
|
Power input
|
1000VA
|
||||||
|
Environment temperature
|
18℃~30℃
|
||||||
|
Environment relative humidity
|
30%~75%
|
||||||
|
Atmospheric Pressure
|
700~1060hpa
|
||||||
|
Environment air velocity of flow
|
<0.3m/s
|
||||||
|
Skin Temperature control range
|
32℃~38℃
|
||||||
|
Skin temperature control accuracy
|
≤0.5℃
|
||||||
|
Skin temperature sensor accuracy
|
±0.3℃
|
||||||
|
Mattress temperature uniformity
|
<2℃
|
||||||
|
Infant Bed tilt angle
|
±10°
|
||||||
|
LED observation light function
|
3W
|
||||||
|
Warm-up time(from 25℃)
|
<30min
|
||||||
|
Heater head horizontal
|
±90°
|
||||||
|
Distance from heater to mattress
|
80cm
|
||||||
|
Mattress size
|
67cm*54cm
|
||||||
|
Timer range
|
0~99h59min
|
||||||
Product detail pictures:




Related Product Guide:
Our pursuit and enterprise aim would be to "Always fulfill our buyer requirements". We carry on to acquire and layout excellent quality items for the two our old and new clients and realize a win-win prospect for our shoppers in addition as us for Top Suppliers Immuno Fluorescence - AW-1A CE approved Medical Neonatal Radiant Infant Warmer – Amain, The product will supply to all over the world, such as: Austria , Qatar , Detroit , Customer's satisfaction is always our quest, creating value for customers is always our duty, a long term mutual-beneficial business relationship is what we are doing for. We are an absolutely reliable partner for you in China. Of course, other services, like consulting, can be offered too.