H7c82f9e798154899b6bc46decf88f25eO
H9d9045b0ce4646d188c00edb75c42b9ek

Clinical biochemistry analyzer Mindray BS 230

Nkọwa dị mkpirikpi:

Aha ngwaahịa:Clinical biochemistry analyzer Mindray BS 230 -Medsinglong
Ọnụ ahịa kacha ọhụrụ:

Nọmba nlereanya:Mindray BS 230
Arọ:Netwọk arọ: n'arọ
Ọnụ ahịa kacha nta:1 Tọọ Tọọ/Ntọọ
Ikike inye:Set 300 kwa afọ
Usoro ịkwụ ụgwọ:T/T,L/C,D/A,D/P,Western Union,MoneyGram,PayPal


Nkọwa ngwaahịa

Mkpado ngwaahịa

Nkọwa ngwa ngwa

ClinicalChemistry Analyzerlaabu akụrụngwa chemistry lab akụrụngwa Clinical biochemistry clinical laabu

Nkwakọ ngwaahịa & nnyefe

Nkọwa ngwugwu:Ngwungwu mbupụ ọkọlọtọ
Nkọwa nnyefe: n'ime 7-10 ụbọchị ọrụ mgbe nnata nke ugwo

Nkọwapụta

Clinicalbiochemistry analyzer Mindray BS 230 -Medsinglong BS-230 Clinical Chemistry Analyzer System function Automatic, Discrete, Random Access, Bench-top STAT sample priority Throughput: Up to 200 tests/hour, up to 400 tests/hour with ISE Measuring principles: Absorbance photometry, Turbidimetry, Ion Selective Electrode technology Methodology: End-point, Fixed-time, Kinetic, optional ISE, Single/Dual/ reagent chemistries, monochromatic / bi-chromatic Original system pack reagent ready to use Close system and open system is optional Reagent / Sample Handling Reagent / Sample tray: 80 ọnọdụ maka reagents na 40 ọnọdụ maka samples na 24-hour refrigerated ngalaba (2 ~ 12 ℃) Reagent olu: 10 ~ 250μl, nzọụkwụ site 0.5μl Sample olu: 2 ~ 45μl, nzọụkwụ site 0.1μl Reagent/Sample nyocha: Nchọpụta ọkwa mmiri mmiri, nchebe nkukota kwụ ọtọ na nyocha ngwaahịa, reagent tupu ikpo ọkụ nyocha: ịsacha akpaaka maka ime na mpụta na-ebufe <0.05% akpaaka ihe nlere anya: pre-dilution na post-dilution koodu mmanya ime. onye na-agụ (nhọrọ) Ike ịkparịta ụka na LIS na bi-directional mode Reaction System: Cuvette: 40 disposable cuvettes Reaction volume: 100 ~ 360μl Ọrụ okpomọkụ: 37 ℃ ± 0.1 ℃ Clinical biochemistry analyzer Mindray BS 230 -Medsinglong ISE Module (optional) Measuring K+, Na+, Cl- Mixing Unit Independent mixing bar Optical System Light Source: Halogen-tungsten lamp Wavelength: 8 wavelengths, 340nm、405nm、450nm、 510nm、546nm、578nm、630nm、670nm Absorption range: 0~4.0 Abs (10mm conversion), resolution 0.0001Abs Stray Light 5.6Abs Control and Calibration Ụdị nhazi nhazi: Linear (otu isi, isi abụọ na ọtụtụ isi), Logit-Log 4P, Logit-Log 5P, spline, exponential, polynomial, parabola Control Iwu: XR, LJ, Westgard multi-rule, Nchịkọta nchịkọta ego, ejima plot Operation Unit Operation System: Windows 8 Interface: RS-232 Working Conditions Power Supply: 200~240V, 50/60Hz, ≤1000VA or 100~130V, 60Hz, ≤1000VA Akụkụ: 690 mm (ogologo) ×595 mm (ịdị elu) Ibu: 47 n'arọ mmiri oriri: ≤ 2 L/H

 


  • Nke gara aga:
  • Osote:

  • Hapụ ozi gị:

    Dee ozi gị ebe a ziga anyị ya.

    Hapụ ozi gị:

    Dee ozi gị ebe a ziga anyị ya.