H7c82f9e798154899b6bc46decf88f25eO
H9d9045b0ce4646d188c00edb75c42b9ek

ʻIkepili lāʻau biochemistry ʻo Mindray BS 230

ʻO ka wehewehe pōkole:

Inoa mea kūʻai:ʻIkepili lāʻau biochemistry ʻo Mindray BS 230 -Medsinglong
Kumukuai Hou loa:

Helu kumu hoʻohālike:Mindray BS 230
Kaumaha:Kaumaha ʻupena: Kg
Ka nui o ke kauoha liʻiliʻi:1 Hoʻopaʻa ʻia
Hiki ke hoolako:300 Sets i kēlā me kēia makahiki
Kūkākūkā uku:T/T,L/C,D/A,D/P,Western Union,MoneyGram,PayPal


Huahana Huahana

Huahana Huahana

Nā kikoʻī wikiwiki

KaukaʻIke Kemikamea hoʻo·keʻe kiʻekiʻe kiʻekiʻe kiʻekiʻe kiʻekiʻe

Puke a me ka lawe ʻana

ʻŌlelo kikoʻī: Pūʻolo hoʻopuka maʻamau
Nā kikoʻī kikoʻī: i loko o 7-10 mau lā hana ma hope o ka loaʻa ʻana o ka uku

Nā kikoʻī

Kaukamea kālai lāʻau biochemistry Mindray BS 230 -Medsinglong BS-230 Clinical Chemistry Analyzer System function Automatic, Discrete, Random Access, Bench-top STAT sample priority Throughput: Up to 200 tests/hour, up to 400 tests/hour with ISE Measuring principles: Absorbance photometry, Turbidimetry, Ion Selective Electrode technology Methodology: End-point, Fixed-time, Kinetic, optional ISE, Single/Dual/ reagent chemistries, monochromatic / bi-chromatic Original system pack reagent ready to use Close system and open system is optional Reagent / Sample Handling Reagent / Sample tray: 80 kūlana no ka reagents a me 40 kūlana no nā laʻana ma 24-hour refrigerated compartment (2 ~ 12 ℃) Reagent volume: 10 ~ 250μl, step by 0.5μl Sample volume: 2 ~ 45μl, step by 0.1μl Reagent/Sample probe: ʻIke wai pae wai, pale kuʻi kūkū a me ka nānā ʻana i ka waihona, reagent pre-warming Hoʻomaʻemaʻe Probe: Holoi ʻakomi no ka loko a me waho Lawe i ka <0.05% ʻO ka hoʻoheheʻe ʻana ma mua: Pre-dilution and post-dilution. mea heluhelu (koho) Hiki ke kamaʻilio me LIS ma ke ʻano bi-directional Reaction System: Cuvette: 40 disposable cuvettes Ka nui o ka pane ʻana: 100~360μl Ka wela hana: 37℃±0.1℃ Clinical biochemistry analyzer Mindray BS 230 -Medsinglong ISE Module (optional) Measuring K+, Na+, Cl- Mixing Unit Independent mixing bar Optical System Light Source: Halogen-tungsten lamp Wavelength: 8 wavelengths, 340nm、405nm、450nm、 510nm、546nm、578nm、630nm、670nm Absorption range: 0~4.0 Abs (10mm conversion), resolution 0.0001Abs Stray Light 5.6Abs Control and Calibration Nā ʻano hoʻohālikelike: Linear (hoʻokahi kiko, ʻelua mau kiko a me nā helu he nui), Logit-Log 4P, Logit-Log 5P, spline, exponential, polynomial, parabola Nā lula Mana: XR, LJ, Westgard multi-rule, Cumulative sum check, twin ʻāpana ʻĀina Hana ʻōnaehana hana: Windows 8 Interface: RS-232 Nā Kūlana Hana Mana Mana: 200~240V, 50/60Hz, ≤1000VA a i ʻole 100~130V, 60Hz, ≤1000VA Ana: 690 mm (lōʻihi) ×580 mm (dep) × 595 mm (kiʻekiʻe) Kaumaha: 47 kg Ka hoʻohana wai: ≤ 2 L/H

 


  • Mua:
  • Aʻe:

  • Waiho i kāu memo:

    E kākau i kāu leka ma aneʻi a hoʻouna mai iā mākou.

    Waiho i kāu memo:

    E kākau i kāu leka ma aneʻi a hoʻouna mai iā mākou.