H7c82f9e798154899b6bc46decf88f25eO
H9d9045b0ce4646d188c00edb75c42b9ek

I-Semi-auto Chemistry Analyzer ehamba phambili AMBA22 |Medsinglong

Incazelo emfushane:

Igama Lomkhiqizo:I-Semi-auto Chemistry Analyzer ehamba phambili AMBA22 |Medsinglong
Intengo Yakamuva:

Inombolo yemodeli:AMBA22
Isisindo:Isisindo sengqikithi: Kg
Inani elincane le-oda:1 Setha Isethi/Amasethi
Ikhono Lokuhlinzeka:300 Amasethi ngonyaka
Imigomo Yokukhokha:T/T,L/C,D/A,D/P,Western Union,MoneyGram,PayPal


Imininingwane Yomkhiqizo

Omaka bomkhiqizo

Imininingwane Esheshayo

I-Stray Light:≤0.5%(absorbance≥2.5)
Ububanzi be-Absorbance: -0.214 ~ 3.000
I-Absorbance Linearity:±1%
Ukuphindaphinda kwe-Absorbance:±0.001
Ukunemba: ≤1%
Carry Over: ≤1%
Ukulungiswa: 1m Abs
Ukuzinza: ≤3mAbs/h

Ukupakisha Nokulethwa

Imininingwane yokupakisha:Iphakheji yokuthekelisa ejwayelekile
Imininingwane yokulethwa: phakathi nezinsuku zokusebenza eziyi-7-10 ngemuva kokuthola inkokhelo

Imininingwane

Izici ze-Semi-Auto Chemistry Analyzer AMBA22:

1.Izindlela Zokuhlaziya:i-kinetic,isikhathi esimisiwe,iphuzu lokugcina,i-absorbance
2.Wavelengths:7 izihlungi ezijwayelekile:340,405,492,510,546,578,630nm,1 ngaphezulu isihlungi ozikhethela sona
3.Isistimu ye-reagent evulekile egcwele
4.Izinto zingahlelwa,inani lezinto elinganqunyelwe
5.Ukwazisa ngezwi, okwenza umsebenzi ube mnandi
6.Isixhumi esibonakalayo sokusebenza kweWindows, inkinobho yesibalo, ukusebenza kwegundane
7.Isikhathi sangempela sokuboniswa kwegrafu nokuphrinta
8.Isici sokulondoloza izibani, impilo ende yesibani
9.Ikhono elikhulu lokugcina, kufika kumiphumela engu-1000,000

Ukucaciswa kwe-Semi-Auto Chemistry Analyzer AMBA22:

Indlela ye-Assay: izinga lokusabela, iphoyinti lokugcina, amaphuzu amabili, ubude begagasi obuphindwe kabili, i-coefficient, izindinganiso eziningi, i-reagent engenalutho, isampula engenalutho, ukumunca endaweni ehleliwe, i-QC, igrafu ye-QC kanye ne-turbidity
I-Temperature System: Ingxenye yokulawula izinga lokushisa ye-PELTIER, 25℃,30℃,37℃,ukunemba: ±1℃
Umthombo wokukhanya: 6V, 10W isibani se-halogen esingaphezu kwamahora angu-2000
Ukunemba kwe-GML:±2nm
I-FWHM: ≤10nm
I-Stray Light:≤0.5%(absorbance≥2.5)
Ububanzi be-Absorbance: -0.214 ~ 3.000
I-Absorbance Linearity:±1%
Ukuphindaphinda kwe-Absorbance:±0.001
Ukunemba: ≤1%
Carry Over: ≤1%
Ukulungiswa: 1m Abs
Ukuzinza: ≤3mAbs/h
Iseli Eligelezayo:iseli eligeleza le-quartz elihlala njalo, ivolumu encane ngu-32uL, futhi iseli eligelezayo elilahlwayo liyakhethwa
Uhlelo Lokusampula: amaphampu akhipha ingcindezi ngokuzenzakalelayo aqinisekisa ukunemba kwevolumu yokumunca
Ivolumu yokukhipha: 200uL ~ 3000uL
Umthamo Wesampula: 10uL ~ 50uL
Uhlelo Olusebenzayo: IWindows XP enomthamo wememori engu-1GB
Isibonisi:10.1'LCD
Phrinta: phrinta umbiko wokuhlola ojwayelekile we-A4
Isixhumi esibonakalayo:RS-232 serial port
Isimo sokusebenza:Izinga lokushisa:10℃-30℃,Umswakama Ohlobene:20% -80%
I-Voltage: AC 85 ~ 264V, ukuzivumelanisa ngokuzenzakalela ngokuya nge-voltage yokufaka
Amandla: ≤100W
Uhlelo Lwekhwalithi: CE

Izithombe Zokusetshenziswa Kwekhasimende Ze-Semi-Auto Chemistry Analyzer AMBA22
Sicela usithinte uma ufuna ukwazi imininingwane eyengeziwe.

Okumaphakathi nevidiyo ye-Semi-Auto Chemistry Analyzer AMBA22
Sicela usithinte uma ufuna ukwazi imininingwane eyengeziwe.


  • Okwedlule:
  • Olandelayo:

  • Shiya Umlayezo Wakho:

    Bhala umlayezo wakho lapha futhi usithumelele wona.

    Shiya Umlayezo Wakho:

    Bhala umlayezo wakho lapha futhi usithumelele wona.