H7c82f9e798154899b6bc46decf88f25eO
H9d9045b0ce4646d188c00edb75c42b9ek

I-AM Anesthesia-Ventilator-machine-AMGA11 iyathengiswa

Inkcazelo emfutshane:

Igama lemveliso:Umatshini we-Anesthesia Ventilator uyathengiswa-AMGA11
Ixabiso langoku: US $ 100-737 / Seti

Inombolo yoMzekelo:AMGA11
Ubunzima:Ubunzima obububo:58Kg
Ubuncinane boMyinge weodolo:1 Seti Iseti/Iiseti
Ukubonelela ngezakhono:IiSeti ezingama-300 ngonyaka
Immimiselo yokuhlawula:T/T,L/C,D/A,D/P,Western Union,MoneyGram,PayPal


Iinkcukacha zeMveliso

Iithegi zeMveliso

Iinkcukacha eziKhawulezayo

Lo matshini we-anesthesia uqukethe iyunithi ephambili, i-anesthetic vaporizer, i-flow meter, i-respirator ye-anesthesia kunye nenkqubo yesekethe yokuphefumula.

Ukupakishwa kunye nokuhanjiswa

Iinkcukacha zokupakisha:Iphakheji yokuthumela ngaphandle eqhelekileyo
Iinkcukacha zokuziswa: phakathi kweentsuku zokusebenza ezi-7-10 emva kokufunyanwa kwentlawulo

Iinkcukacha

Umatshini we-Anesthesia Ventilator uyathengiswa-AMGA11

 

AMUmatshini weAnesthesia Ventilator-AMGA11Isishwankathelo

Lo matshini wokuthomalalisa i-AMGA11 sisixhobo esibalulekileyo sokuthomalalisa iintlungu kwigumbi lokusebenza.Umsebenzi walo kukubonelela ngeoksijini kunye ne-arhente yokuthomalalisa kwisigulane esifuna ukudlula kwi-anesthesia operation kunye nokwenza ulawulo lokuphefumla. ubunzima bomzimba obunzima kune-10kg. Lo mshini we-Anesthesia we-AMGA11 uxhotyiswe nge-vaporizer echanekileyo ezinikeleyo ye-anesthetic kunye nesixhobo sokukhusela ukukhusela i-cyanosis kunye nenkqubo ye-alamu eyimfuneko.Ngexesha le-anesthesia, imisebenzi yokuphefumla yesigulane inokulawulwa ngokusebenzisa i-microcomputer elawulwa yi-pneumatic electronicly controlledsynchronizing anesthesia respirator.Inxalenye nganye yoqhagamshelo kumatshini wonke ilujongano olusemgangathweni.Isixhobo sokufunxa i-lime yesoda esebenza kakuhle kakhulu kunye nomthamo omkhulu unokunciphisa ukuphefumla kwakhona kwekharbon diokside sisigulana.

 

 

Iimeko zokusebenza zeAMGA11Umtshini weAnesthesiae:

———Iqondo lobushushu bokuhlala: 10 ~ 40 ℃ ;———Ukufuma okuhambelanayo: akukho ngaphezu kwe-80 %;——–Uxinzelelo lomoya: 860 hPa ~ 1060 hPa.——–Amandla afunekayo: ~220-240/60V, 50V, 50V, Hz. I-40VA, ukuba isekelwe kakuhle.---Imfuno yomthombo womoya: i-oksijeni yonyango kunye negesi ehlekayo kunye noxinzelelo olulinganisiweyo olusuka kwi-0.3 ukuya kwi-0.5MPa. Ingqalelo: umbane we-AC osetyenziselwa umatshini wokuthomalalisa kufuneka usekelwe kakuhle. Qaphela: umatshini wokuthomalalisa esetyenzisiweyo kufuneka ixhotyiswe nge-carbon dioxide esweni ehambelana ne-ISO 9918:1993, i-oksijini esweni ethobela i-ISO 7767:1997 kunye ne-gasvolume monitor ephelelwayo ehambelana ne-51.101.4.2 yeSixhobo soMbane sezoNyango iCandelo II: IiMfuno eziZodwa zoKhuseleko kunye nokuSetyenziswa okuSisiseko kweNkqubo ye-Anesthesia . I-Anesthesia Ventilator ye-AMGA11 yeZakhiwo zeempawu kunye neMigaqo yokuSebenzaLo matshini we-anesthesia uquka iyunithi ephambili, i-anesthetic vaporizer, i-flow meter, i-anesthesia respirator kunye nenkqubo yesekethe yokuphefumula.

Eyona Ventilator yeAnesthesia ithengiswayo-AMGA11 yobuchwephesha

I-1 Imodi yokusebenza: i-circulatory ivaliwe, i-semi-closed kunye ne-semi-open.2 Imfuno yegesi: i-oksijeni yonyango kunye negesi ehlekayo kunye noxinzelelo olusuka kwi-0.3MPa ukuya kwi-0.5 MPa.3 Impazamo enkulu yesixhobo sokuvavanya uxinzelelo akufanele idlule ± (4 Ipesenti yokufundwa kwesikali esipheleleyo + i-8% yokufunda kwangempela) .4 I-oksijini kunye negesi ehlekayo, umlawuli okhethekileyo woxinzelelo kunye ne-valve yokukhusela iya kunikwa.I-exhaustpressure yevalve yokhuseleko akufanele ibe phezulu kune-6 kPa.5 Uluhlu olubonisa uluhlu lwe-oksijeni kunye ne-gas ehlekayo imitha yokuhamba kwegesi: 0.1 L/min ~ 10 L/min. I-100%, ukuchaneka kwesikali kufuneka kube phakathi kwe-± 10% yexabiso elibonisiweyo.6.Umitha wokuhamba uxhotyiswe nge-oxygen-laughing gas device control proportional control.Xa i-oxygen concentration kwi-gas exutywe i-N2O / O2 ihanjiswe ngumshini we-anesthesia ayikho ngaphantsi kwe-20% (V / V) okanye i-FiO2 ingaphantsi kwe-20%, umatshini uya kukhupha i-analarm.7. Xa uxinzelelo lwe-oksijini yomshini we-anesthesia yi-0.20MPa ± 0.05MPa, umatshini uphakamisa i-alamu yoxinzelelo lwe-gassource ephantsi okuyiyona nto ibaluleke kakhulu, kwaye ivala igesi ehlekayo ehanjiswa kwi-gas outlet eqhelekileyo.8.I-Oxygen Flush: 25~75 L/Min;9.Uluhlu lohlengahlengiso lwegesi ye-anesthetic ye-vaporizer: 0~5%, impazamo ehambelanayo ± 20%.10.Uxinzelelo lokukhupha i-valve yokhuseleko lwesiphaluka sokuphefumula alukho ngaphezu kwe-6 kPa.11.I-Anesthesia ventilator11.1 Indlela yokuphefumla:IPPV,SIPPV,Manu11.2 Amaxesha okuPhumla:4~40bpm11.3 I/E Ratio:1:1.5~1:411.4 Tidal Volume:50~1500mL11.5 Ptr:-10~10hPa11. Ukungena komoya okulawulwayo kunye nexesha lokutshintsha umoya oncediswayo: 6s11.7 Ubuninzi boxinzelelo lokhuseleko: ≤ 12.5 kPa.11.8 Uluhlu lwemida yoxinzelelo: 1~6 kPa11.9 I-alamu yoxinzelelo lomoya: uluhlu lohlengahlengiso lomda we-alamu ephezulu: 0.3kPa ~ 6 kPa, impazamo evumelekileyo ± I-0.2 kPa, okanye ± 15% (nokuba yeyiphi na enkulu), umatshini kufuneka ngokukhawuleza aphakamise i-alam yomgangatho ophezulu xa uxinzelelo lwe-airway lufikelela kwixabiso le-alam;umda we-alamu osezantsi usuka kwi-0.2 ukuya kwi-5 kPa kwaye impazamo evumelekileyo yi-±0.2 kPaor ±15% (nokuba yeyiphi na enkulu).Umatshini kufuneka uphakamise ngokukhawuleza i-alamu yezinga eliphakathi xa i-airwaypressure ihla kwixabiso le-alamu kwaye imeko enjalo ithatha i-4 ukuya kwi-15s. uluhlu lohlengahlengiso lomda we-alamu ophantsi ngu-0 ~ 1800ml, impazamo evumelekileyo yi-±20% kwaye umatshini kufuneka uphakamise i-alamu yezinga eliphakathi.3.11.11 Umthamo we-ventilation ephantsi komda we-alamu: uluhlu lohlengahlengiso luyi-0 ~ 12 L / min, kunye nephutha elivumelekileyo ± 20%.Umthamo wokungenisa umoya ophezulu we-alamu umiselwe ukuba ube yi-25 L / min, impazamo evumelekileyo yi-±20%kwaye umatshini kufuneka aphakamise i-alamu yezinga eliphakathi.3.11.12 I-alarm yesiphambeko sombane: umatshini kufuneka anike i-alamu evakalayo xa kukho amandla. Ukucima kunye ne-alarm kufuneka ihlale ngaphezu kwe-120s.3.11.13 Ixesha lokuthulisa isignali ye-alam evakalayo kufuneka libe ngaphantsi kwee-120s.Ubume be-alam akufuneki bucinywe kwaye isignali ye-alam ebonwayo ayifanelanga iphazamiseke.3.11.14 Ibhetri yexesha likaxakeka kufuneka ibe yibhetri yeasidi ekhokelayo enombane olinganisiweyo ophumayo we-DC 12V.Ubude bexesha lokusebenza kwesixhobo sokuphefumla esiqhutywa yibhetri kufuneka sibe ngaphezu kwe-60min.  

 

 

Balisa intengiso eshushu kunye nomatshini ophathwayo we-anesthesia ophathwayo

 

AMGA07PLUS AMPA01 I-AMVM14
AMGA15 AMVM06 AMN31

AM TEAM umfanekiso

Wamkelekile kwi-medicalequipment-msl.com.

Ukuba unayo nayiphi na imfuno kwizixhobo zonyango, nceda uzive ukhululekile ukuqhagamshelanacindy@medicalequipment-msl.com.


  • Ngaphambili:
  • Okulandelayo:

  • Shiya uMyalezo Wakho:

    Bhala umyalezo wakho apha kwaye uwuthumele kuthi.

    Shiya uMyalezo Wakho:

    Bhala umyalezo wakho apha kwaye uwuthumele kuthi.